Safe operation of maritime DC systems with challenging and complex topologies
Astrol and Astrolkwx recognized the trend toward implementing DC grids on board vessels and the necessity for adequate protection components at an early stage (2014). This led to the development of a fully matured range of solid-state DC breakers (SSDCBs), ready for the market. Our solid-state DC breakers allow safe operation of maritime DC systems with low inductance and offer a variety of additional benefits.
How it began
Specifications and requirements
This meeting resulted in a set of electrical and mechanical specifications, and future product requirements such as speed, certification, communication, and current and voltage ratings. Following the requirement discussion, we started the product development process. This process included investigation, review, design, production, testing, and certification. The first certified DC breakers were introduced to the market in 2019, and since then have evolved to higher ratings with additional functionalities into an extensive range of 1.5 kV (0.35 – 5 kA) IGBT-based solid-state DC breakers.
Optimal solutions for enabling multi-bus and ring systems
Our solid-state breakers have demonstrated their capability in multiple applications, serving as bus tie and enabling zone protection in multi-bus and ring systems. With an extensive reference list of over 100 successfully deployed breakers, we contribute to the safe operation of fully electric, hybrid vessels, and workboats (such as DP3 vessels) with improved sustainability.
Innovative marine system integrators choose our IGBT-based solution for the following reasons:
- Applicability in low inductance circuits without any added inductance.
- Cut off current restricted from reaching damaging levels due to ultra-fast interruption (8 – 10 µs).
- DNV- and CCS certified.
- System independent solution, applicable in any brand or type of drive systems.
- Compact and modular design.
- Wide current range from 0.35 – 6 kA nominal.
- DC Voltage up to 1500 V DC nominal.
- DC-ring zone protection with fault isolation and ride through capability during a short circuit for each current direction.